Water Pump Testing Report
The pump npsh.
Water pump testing report. Yes no n a c. 031 765 1900 tel. Pump speed n rpm water temperature t c inlet pressure pin kpa outlet pressure pout kpa motor torque t nm flow rate q l s density of water kg m 1 50 750 26 7 2 6 18 5 0 62 0 04 997 2 50 750 27 2 2 7 18 3 0 64 0 12 996 3 50 750 26 7 2 3 17 7 0 64 0 21 997 4 50 750 26 9 2 2 17 0 0 66 0 29 997 5 50 750 27 1 1 6 15 4 0 65 0 40 997 6 50 750 27 4 1 3 14 0 0 67 0 49 996 7 50 750 26 7. In such cases the attained values will be converted to field condition by engineering calculation.
By december 31 2011 and is being designed to treat water at pumping rates as high as 2 500 gpm. The pump might be designed for crude oil but in the shop will be tested by the water. Inspections are to be performed with water supplies including fire pumps in service unless the impairment procedures of chapter 11 of nfpa 25 are followed. Yes no n a b.
The principle of a pumping test involves applying a stress to an aquifer by extracting groundwater from a pumping well and measuring the aquifer response to that stress by monitoring drawdown as a function of time. Has the fire pump remained in service since the last inspection. Preliminary aquifer test characterization results for well 299 w15 225. The new facility will treat the eight contaminants of concern identified in the final record of decision epa et al.
Final report on the drilling pump testing and water quality analysis of two 2 new boreholes in the ozwathini and nhlangakazi areas in the ilembe district municipality hillcrest 3650 hillcrest office gauteng office unit 3 burnside office park 173 tulbagh street 1 builders way pomona hillcrest 3610 kempton park 1619 p o. An important feature of the report is the units used to measure the contaminant level in your water. 2008 including carbon tetrachloride. The basic principle of a pumping test is that if we pump water from a well and measure the pumping rate and the drawdown in the well then substitute these measurements into an appropriate formula.
Once the lab has completed testing your water you will receive a report that looks similar to figure 1. These measurements are then incorporated into an appropriate well flow equation to calculate the hydraulic parameters of the aquifer. Testing commissioning of water booster pump set method statement. Part i owner s section a.
Subsequently you need to check bearing housing and shaft vibration fft spectrum plot at each data point from minimum to maximum flow to ensure the vibration values are within acceptance range. Is the fire pump in service. It will contain a list of contaminants tested the concentrations and in some cases highlight any problem contaminants. By webmaster november 24 2016.
Supporting phase i of the 200 zp 1. 031 765 1935. A pumping testis a field experiment in which a well is pumped at a controlled rate and water level response drawdown is measured in one or more surrounding observation wells and optionally in the pumped well control well itself.